Single-circuit metering & monitoring diris_989.psd DIRIS A-40 Multi-function meters The solution for > Industry > Building > Infrastructure > Data center Strong points DIRIS A-40 Configuration with EasyConfig Systems. Function The DIRIS A-40 is a panel-mounted power monitoring device (PMD). It is designed for measuring, monitoring and reporting electrical energy. Advantages Assisted configuration The configuration wizard guides the user in a step by step process to configure the DIRIS A-40. It also detects and corrects configuration errors. This cuts the commissioning time in half and always delivers a reliable result. Smart sensors Three current sensor formats (solid-core TE, split-core TR/iTR and Rogowski coil TF) allow integration of the DIRIS A-40 into new and existing electrical installations. Connected to the Cloud The range comprises IoT ready connected products that enable data to be exported automatically for remote operation without any limit on time, distance and time in storage. Better than revenue grade Compliant with the IEC 61557-12 standard, guaranteeing the quality and accuracy of the Power Meter: • Class 0.2 for the meter alone. • Class 0.5 from 2% to 120% of the rated current (full scale), for the global measurement chain (with TE/iTR/TF current sensors). Functions Multi-measurement • Currents - I1, I2, I3, In, Isystem • Voltages & frequency - V1, V2, V3, VN, Vsystem, U12, U23, U31, Usystem, f • Powers - P1, P2, P3, ΣP, Q1, Q2, Q3, ΣQ, S1, S2, S3, ΣS - Predictive powers ΣP, ΣQ, ΣS • Power factor - PF1, PF2, PF3, ΣPF • Cos ϕ & tangent ϕ - Instantaneous values per phase Metering • Active energy: +/- kWh • Reactive energy: +/- kvarh • Apparent power: kVAh • Multi-tariff (8 max.) • Hour Meter Quality • Voltage Unbalance - Vdir, Vinv, Vhom, Udir, Uinv, Unba, Vnba, Vnb, Unb • Current unbalance - Idir, Iinv, Ihom, Inba, Inb • Total harmonic distortion - Currents THDi1, THDi2, THDi3,THDiN, TDDI - Phase-to-neutral voltage THDv1, THDv2, THDv3 - Phase-to-phase voltage THDu12, THDu23, THDu31 • Individual harmonics up to 63rd - Currents: I1h, I2h, I3h, INh - Phase-to-neutral voltage: V1h, V2h, V3h - Phase-to-phase voltage: U12h, U23h, U31h • Quality events - Voltage sags, interruptions and swells EN50160 - K factor & Crest factor • Events according to EN 50160 - Voltage sags, interruptions, voltage swells Monitoring of protective devices • Auxiliary contact monitoring • Report and alarm on trips • Number of operations Demand profiles and historical records • Active, reactive and apparent power • Currents, voltages and frequency Alarms • Alarms for all electrical values, events and input status changes, boolean combinations of multiple alarms • Time-stamping of events Communication • DIRIS A-40 RS485 Modbus as standard • DIRIS A-40 Ethernet Modbus • DIRIS A-40 PROFIBUS DPV1 Inputs • 3 digital inputs - Power supplied from DIRIS A-40 or an external source - Function: logical status, status of circuit breaker, pulse metering of multifluid meters. • 2 logical outputs - Function: Command, energy pulse output, load shedding, alarm 289 General Catalog UL/CSA Ed. 3 Conformity to standards > UL 61010-1 CSA-C22.2 61010-1 File E257746 > IEC 61557-12 > ISO 14025 > CEC compliant The DIRIS A-40 offers a range of functions for measuring voltage, current, power, energy and quality. It allows the analysis of one single-phase or three-phase load. > Assisted configuration > Connected to the cloud > High-precision measurment chain > Smart sensors Integrated technologies